1987 · Карбюраторная система питания — страница 42

Adjustment Procedures · 42

1987-Montero · Fuel System Carb a · страница 42 из 86 · Открыть оригинал PDF ↗

Иллюстрация 1, страница 42

Adjustment Procedures

CHECKING THE THERM0 VALVE (FOR AAP CON- TROL) N14FZAB

(1) Disconnect the vecuum hose (black) from the therm0 valve
and connect a manual vacuum pump to the therm0 valve.
(2) Apply a negative pressure of 66 kPa (10.0 psi) to the
therm0 valve.
I
When engine is cold[coolant Negative pressure is not
temperature 30°C (86°F) or lower1 applied (leakage).
After engine warm-up[coolant Negative pressure is
temperature 50°C (122°F) or higher] applied (no leakage). I

(3) If incorrect, replace the therm0 valve.

Caution

1. Do not use a wrench or similar tool at the resin part
when removing or installing the therm0 valve.
2. When installing, apply a coating of the specified adhe-
sive to the threaded part, and then tighten at a torque of
20-35 Nm (14-25 ftlbs.).

Specified adhesive : 3M Adhesive Nut Locking No.
4171 or equivalent
REPLACEMENT OF FUEL FILTER N14FCAB

Refer to GROUP 0 LUBRICATION AND MAINTENANCE-Fuel
Filter (Replace)

Иллюстрация 2, страница 42
Иллюстрация 3, страница 42
Иллюстрация 4, страница 42
Иллюстрация 5, страница 42
Иллюстрация 6, страница 42
Иллюстрация 7, страница 42
Иллюстрация 8, страница 42
Иллюстрация 9, страница 42
Иллюстрация 10, страница 42
Иллюстрация 11, страница 42
Иллюстрация 12, страница 42
Иллюстрация 13, страница 42
Иллюстрация 14, страница 42
Иллюстрация 15, страница 42
Иллюстрация 16, страница 42
Оригинальная страница руководства
14-42 FBC SYSTEM-Service Adjustment Procedures
100%

Назад
Сверху