1987-Montero · Fuel System Carb a · страница 67 из 86 · Открыть оригинал PDF ↗


20. REMOVAL OF FEEDBACK SOLENOID VALVE (FBSV)
Using a screwdriver or other tool with a thin flat end, push the
stopper portion and remove the two terminals from behind the
connector.
Caution
Ensure that the terminal is not bent during removal of the
connector.
NOTE
Unless the terminals are removed from the connector, the
feedback solenoid valve cannot be removed from the float
chamber cover.
25. REMOVAL OF SLOW CUT SOLENOID VALVE (SCSV)
(1) Remove the retainer and pull out the slow cut solenoid
valve.
Caution
When removing the valve, do not hold the leads but
hold the body.

(2) Using a screwdriver or other tool with a thin flat end, push
the stopper section and remove the two terminals from
behind the connector.
Caution
Ensure that the terminal is not bent during removal of
the connector.

(1) Grind away the head of the two rivets of the bimetal as-
sembly using an hand grinder or other tool. Remove the
screw.
(2) Remove the plate, the bimetal assembly and the packing.
(3) Remove the remaining rivet bodies using a pin punch etc..


(4) Using a screwdriver or other tool with a thin flat end, push
the stopper section and remove the terminal from behind
the connector.