ServiceAdjustment Procedures

Disconnect the spring at the support side

3Placethe springSOthat it is in parallel withthe load-
sensing proportioning valve,and then pull in the direction
indicated by arrowA so that its length H shown in the
figure (the length between its ends) is as noted below.
NOTE

Иллюстрация 1, страница 92

At this time the lever is pressed all the way to the load-
sensing proportioning valve side_

Check at this time whether or not the output fluid's pres-
sure,relativetOthe load-sensingproportioningvalve 's
input fluid pressure, is within the standard value

Standard value:

Таблица в оригиналеТаблица: оригинал страницы 92
Распознанный текст таблицы — требует сверки с оригиналом
ItemsSpring
length H
mm (in.)
Input fluid
pressure MPa
(kg/cm? ,
psi)
Output fluid
pressure MPa
(kg/cm? ,
psi)
2-door models227.5
(9.0)
10 (100,
14221
5.37-6.27
(53.7-62.7 ,
763.8-891,8)
18 (180, 256017.17-8.47
(71,.7-84.7 ,
1019.8-1204.7)
4-door models226_
(8.91
10 (100, 142216.14-7.04
(61.4-70.4,
873.3- 1001.3)
18 (180,
2560)
7.94-9.24
(79.4-92.4,
1129.3-1314.2)

In the same manner as in step 3._check whether or not
theoutput fluid'spressure,relativetothe load-sensing
proportioningvalve'sinputfluidpressureiswithinthe
standard valve when the spring's length H is the dimen-
sion noted below

Standard value:

Таблица в оригиналеТаблица: оригинал страницы 92
Распознанный текст таблицы — требует сверки с оригиналом
ItemsSpring
length
mm (in.)
Input fluid
pressure MPa
(kglcm?, psi)
Output fluid
pressure MPa
(kglcm? psi)
2-door models255.6
(10.1)
18 (180, 2560113.1-15.1
(131-151,
1863.3-2147.7)
4-door models257.7
(10.1)
25601
18 (180,
10.4-12.4
(104-124,
1479.2-1763.7)

After making the check, install the springDisconnect the
pressuregaugesfromtheload-sensingproportioning
valve and bleed the air.

Fab.1991

PWJE9O8B

Оригинальная страница руководства
Страница 92
100%

Назад
Сверху