Pajero II Workshop Manual 1991 · FUEL · страница 171 из 339 · Открыть оригинал PDF ↗
Текст распознан со скана. Числа и обозначения можно сверить с оригиналом ниже.


Wave pattern observation points
Check that the standard wave pattern appears when the stepper motor is operating_
(Point AJ:Presenceor absenceof inducedelectromotive force from themotorturning: (Refer to the
abnormal wave pattern )
Распознанный текст таблицы — требует сверки с оригиналом
| Contrast with standard wave pattern | Probable cause |
|---|---|
| Induced electromotive force does not appear or IS extremelv small | Motor is malfunctioning |
| Height of coil reverse electromotive force (Point B): | |
| Contrast with standard wave pattern | Probable cause |
| Coil reverse electromotive force does not appear extremely smal. | Short in the coil |
Abnormal wave pattern
Cause of problem
Motor is malfunctioning(Motor is not operating )
Wave pattern characteristics
Induced electromotive force from the motor turning does
not appear.
01p0209