VARIABLE INDUCTION CONTROL SOLENOID VALVE <DOHC>


OPERATION
The variable induction control solenoid valve is
an ON-OFF type of solenoid valve, and converts
the vacuum motor pressure into the intake mani-
fold pressure or atmospheric pressure inside the
vacuum tank
Battery voltage is supplied to the variable induc-
tion control valve via the control relay. When the
enginecontrolunit turns thepower transistor
inside the unit ON, current flows to introduce the
intake manifold vacuum into the vacuum motor,
This causes the vacuum motor to operate.
Thus, the control valve will close:
Проверка
Using MUT-II
Распознанный текст таблицы — требует сверки с оригиналом
| Function | Item No: | Drive contents | Check condition | Normal condition |
|---|---|---|---|---|
| Actuator test | Solenoid valve is switched from OFF to ON, | Ignition switch: ON | Operating noise is heard when driven |