Standard wave pattern
Observation conditions

Time
ZFU1204
Wave pattern observation points
Check that the standard wave pattern appears when the stepper motor is operating:
(Point A}:Presence or absence of induced electromotive force from the motor turning: (Refer to the
abnormal wave pattern )
Распознанный текст таблицы — требует сверки с оригиналом
| Contrast with standard wave pattern | Probable cause |
|---|---|
| Induced electromotive force does not appear or is extremely small, | Motor IS malfunctioning |
| Height of coil reverse electromotive force (Point B): | |
| Contrast with standard wave pattern | Probable cause |
| Coil reverse electromotive force does not appear or is extremely small | Short in the coil |
Abnormal wave pattern
Cause of problem
Motor is malfunctioning: (Motor is not operating:)
Wave pattern characteristics
Induced electromotive force from the motor turning does
not appear,

HARNESS INSPECTION
Measure the power supply voltage
of idle speed control servo.
Idle speed control servo
connector: Disconnected
Ignition switch: ON
Voltage (V)
SV