(3) Connect the vacuum pump (Mighty Vac) to nippleA"
(4) Check the air flow with the vacuumpump (Mighty Vac)
whenbatteryvoltageisappliedbetweenthe idle-up
solenoidvalveterminals,andwhen battery voltageis
removed:


NOTE
*2
Atnegative pressure can be felt, but atnegative
pressure cannot be felt:
(5) Measuretheresistancebetweenthe idle-up solenoid
valve terminals.

approx: 40 Q
Standard value:
ACCELERATOR OPENER SOLENOID VALVENO.2 (FOR ANTI-LOCK BRAKE) CHECK
NOTE
When disconnecting the vacuum hose, always makea mark
so that the hose can be connected at the original position:
Remove the idle-up solenoidvalvefromthe hydraulic
unit;
2Measure the resistance between the solenoid valve ter-
minals.
Standard value:<TYPE 1> 33-39 Q
<TYPE 2> 37-44 Q