MANUALS · FUEL [13] · страница 171 из 340 · Открыть оригинал PDF ↗
Текст распознан со скана. Числа и обозначения можно сверить с оригиналом ниже.

Time
7Fu1204
Wave pattern observation points
Check that the standard wave pattern appears when the stepper motor is operating
Presence or absence of induced electromotive force from the
(Point A}:
abnormal wave pattern )
motor turning: (Refer to the
Распознанный текст таблицы — требует сверки с оригиналом
| Contrast with standard wave pattern or is extremely small: Induced electromotive force does not appear | Probable cause Motor is malfunctioning |
|---|---|
| Height of coil reverse electromotive force _ Point B}: Contrast with standard wave pattern or is extremely small_ Coil reverse electromotive force does not appear | Probable cause Short in the coil |
(Point B}:Height of coil reverse electromotive force _
Contrast with standardwave pattern
Coil reverse electromotive force does not appearor is extremely small_
Abnormal wave pattern
Cause of problem
Motor is malfunctioning: (Motor is not operating )
Wave pattern characteristics
Induced electromotive force from the motor turning does
not appear