(5) Measuretheresistancebetweenthe idle-upsolenoid
valve terminals

Standard value:
approx: 40 Q
ACCELERATOR OPENER SOLENOID VALVE NO.2 (FoR ANTI-LOCK BRAKE) CHECK
NOTE
When disconnecting the vacuum hose, always makea mark
so that the hose can be connected at the original position.
Removethe idle-upsolenoidvalvefromthehydraulic
unit.
2Measure the resistance between the solenoid valve ter-
minals
Standard value:<LH drive' vehicles> 38-44 Q
<R.H. drive vehiclesz 33-39 Q
Connecta hand vacuum pump to the nippleA"
Check airtightness by applyinga vacuum withvoltage ap
plied directly from the battery to the solenoid valve ter-
minal and without applying voltage
Распознанный текст таблицы — требует сверки с оригиналом
| Battery voltage | Solenoid valve B nipple | Normal condition |
|---|---|---|
| Open | Vacuum leaks | |
| Applied | Blocked with finger | Vacuum maintained |
| Not applied | Open | Vacuum maintained |
Mitsubishi Motors CorporationJun: 1994