SELF-DIAGNOSIS CHECKING
Self-diagnosis checking is performed when there hasbeen
an automatic cancellation, without cancel switch operation.
(1)Note that the diagnosis check connector is located under
the driver's side instrument panel:
Connect the multi-use tester's or MUT-II's socket and
connectortotheaccessoriessocketandtheself-
diagnosis check connector, and set the tester:
Caution
Theignitionswitchshouldalwaysbeturnedoff
when connecting or disconnecting the tester
Use the multi-usetesterorMUT-II accordingtoits
operationinstructions;displaythediagnosiscode
number and then check
(2) When diagnosis code No. is displayed,check by referring
to the check chart applicable to that number.
ERASURE OF DIAGNOSIS CODE
Diagnosis codes are memorized until battery power source is
disconnected.It, however,can be erasedwithout removing
battery terminal by the following procedure:
Turn the ignition switch to ON_
2_With thecontrol switch inthe SETposition,pressthe
main switch to ON,and withinsecond, turn the control
switch to RESUME
3Turn thecontrolswitchback to the SETposition,and
turn the stop lamp switch to ON fora continuous period
of 5 seconds or more.
Check the self-diagnosis code, ad check that the abnor-
mal code is erased anda normal code is output.
DIAGNOSIS DISPLAY PATTERNSAND CODES
Распознанный текст таблицы — требует сверки с оригиналом
| Code No_ | Probable cause | Check chart No_ |
|---|---|---|
| Abnormal condition of motor-driven vacuum pump system | No | |
| 12 | Abnormal condition of vehicle-speed signal system | No_ |
| 15 | Control switch malfunction (when SET and RESUME switches switched ON simultaneously ) | No. 2, |
| 16 | Abnormal condition of ECU | No. 7, 8, |
| 17 | Abnormal condition of throttle position sensor <3000, 3500> Abnormal condition of idle switch <3000, 3500> | No. 11 |