6.CHECKING THE MOTOR-DRIVEN VACUUM PUMP CIRCUIT <Vehicles built from November, 1993>

Иллюстрация 1, страница 316

Description of operation

HOLD MODE

When driving at 40 km/h (25 mph) and the main
switch is pressed to ON and the control switch is
turnedtotheSETposition,thecontrolunit
receives'setsignal_Thecontrolunit stops
current from flowing to the motor-driven vacuum
pump, andmakes current flowtothe solenoid

coils in the control valve and the release valve to
close both valves together_

Also, after reaching the desired speed, the motor-
driven vacuum pump and the control valve turn
ON and OFF repeatedly according to the driving
conditions