ACCELERATIONMODE
Whenthecontrolswitchismovedtothe
RESUMEposition,thecontrolunitreceives
'resumesignalThe control unit controls current
flow to the motor-driven vacuum pump, and con-
trols current flow to the solenoid coils in the con-
trol valve and the release valve to close both val-
ves
together.
DECELERATION MODE
WhenthecontrolswitchismovedtotheSET
position, the control unit receivessetsignal:
The control unit stops current from flowing to the
motor-drivenvacuumandcurrent
pump;stops
from flowingtothesolenoid coilin thecontrol
valve toopenthevalveAt thesame time, the
current flowing to the solenoid coil in the release
valve is stopped, closing the valve
RELEASE MODE
Whenthecontrolswitch ismovedto theCAN-
CEL position, the control unit receives'cancel'
signal: The control unit stops current from flowing
to the motor-driven vacuum pump, and stopscur -
rent from flowing to the solenoid coils in the con-
trol valve and the release valve to open both val-
ves together.
Troubleshooting hint
Diagnosis-No. 11 (automatically cancelled) ECU terminal voltage
Распознанный текст таблицы — требует сверки с оригиналом
| Terminal No. | Signal | Hold | ModefTermi Acceleration | nal voltage (V) Deceleration | Release |
|---|---|---|---|---|---|
| 26 | Motor-driven vacuum pump drive | System voltage | System voltage | ||
| 13 | Control valve open/close | System voltage | System voltage | System voltage | |
| 12 | Release valve open/close | System voltage |